ICU Ventilators

Leading Wholesale Trader of schiller graphnet advance icu ventilator, schiller sophie ventilator, schiller graphnet ts ventilator, schiller aquilon ts ventilator and neonatal ventilator - graphnet neo from Mohali.

Schiller Graphnet Advance Icu Ventilator

Request Callback

Get Latest Price

Product Brochure
Patient TypeUniversal-Adult, Paediatric & Neonatal Ventilator.
Ventilation ModeInvasive & NIV
ApplicationICU & OT
Display Size12.1” TFT- LED colour touchscreen display
Requirement TypeNew
BrandSchiller
Model Name/NumberGraphnet Advance
Patient Age GroupPaediatric, Neonatal, Adult
Mounting TypeICU
Touch Screen PresentYes
Display Resolution (H) x (V)12.1” TFT- LED colour touchscreen display
Advanced ModesPRVC, SIMV (PRVC) + PSV, APRV, MMV + Pressure Support, PSV + assured volume, VSV
Dedicated neonatal ventilation modesTCPL, SIMV (TCPL) + PSV, N-CPAP, Non-Invasive Ventilation

Minimum order quantity: 1 Piece

Universal-Adult, Paediatric & Neonatal Ventilator.

Features
  • 12.1” TFT- LED colour touchscreen display to view waveforms  &  loops  simultaneously
  • Proximal Flow Sensor for neonatal patient category
  • Advanced modes like PRVC, SIMV (PRVC) + PSV, APRV, MMV + Pressure Support, PSV + assured volume, VSV
  • AVA  –  Adaptive  Ventilatory  Assistance
  • High Flow Oxygen Therapy (HFOT / HFNC) 
  • Dedicated neonatal ventilation modes like TCPL, SIMV (TCPL) + PSV, N-CPAP, Non-Invasive Ventilation
  • Tidal volume correction according to BTPS 
  • Endo tracheal tube, altitude and circuit compliance compensation & leak compensation in all modes
  • Integrated nebulizer ( Volume Compensated & Inspiratory Synchronize)
  • Advanced Lung Mechanism Calculations: Auto-PEEP and trapped Volume, WOBi, Exp. Time Constant, P/V Flex Monitoring, Slow Vital Capacity, Pi Max (NIF), Oxygen Index PaFi
  • SBT – Spontaneous Breathing Trial
  • Stress Index
  • Suction % O2 for suction sequence with variable FiO2 
Optional
  • Capnography (Mainstream) – Curves of CO2 / Time and Volumetric Capnography (CO2 / VT), Measurements of EtCO2 Alveolar Ventilation, Dead Space, CO2 Elimination (VCO2), VD / VT Ratio, CO2 expired volume (VTCO2)
  • Physiological Dead Space 

Schiller Sophie Ventilator

Request Callback

Get Latest Price

Product Brochure
Patient TypeNeonatal
Ventilation ModeInvasive & NIV
ApplicationICU & OT
Display Size12 inch
Requirement TypeNew
Non-Invasive ModesnCPAP, NIPPV, SNIPPV (optional), PC-HFO (optional)
Invasive ModesCPAP,PC-IMV,PC-Ass./Cont.,PC- SIMV,CPAP+HFO & PC-HFO(optional),Volume Guarantee(Vlimit/Vtar Modes)

Minimum order quantity: 1 Piece

The new Innovative Neonatal Ventilation System with Conventional and High Frequency Oscillation Ventilation.

SOPHIE stands as a reliable and efficient solution for neonatal and paediatric care, providing the flexibility, precision, and monitoring required to manage critically ill infants. Whether it’s the automatic synchronization of NIV or real-time oxygen saturation adjustments, SOPHIE is built to provide seamless, adaptive, and comprehensive care. 3 in 1 (Conventional , NIV, HFOV) device with an intuitive operating concept.

Features
  • Integrated High-Frequency Oscillation (HFO): Activate with a single button for precise care
  • Heated Electronic Flow Sensor: Accurately measures flow rates and tidal volume (Vt) with minimal dead space, preventing condensation 
  • Automatic servo-controlled Integrated Humidification: Optimally heats and humidifies respiratory gas for the patient and prevents condensation
  • Synchronized Non-Invasive Ventilation (NIV): External respiration sensor syncs NIV with abdominal movements for real-time adaptation (Optional)
  • User-friendly 12″ Touchscreen Interface: Intuitive touchscreen panel for easy adjustments and monitoring Comprehensive Safety System 

Comprehensive Safety System

  • Invasive Ventilation Modes: CPAP, PC-IMV, PC-Ass./Cont., PC- SIMV, CPAP+HFO & PC-HFO (optional), Volume Guarantee (Vlimit / Vtar Modes) 
  • Non-invasive Ventilation Modes: nCPAP, NIPPV, SNIPPV (optional), PC-HFO (optional)

Optional

  • SPO2C (SpO2 Controller): Automatically maintains optimal oxygen saturation, reducing risks like brain damage and blindness in neonates. It works independently of the selected ventilation mode and ensures that patients are within the defined SpO2 target range to a level of approx. 80%

 

 

Schiller Graphnet TS Ventilator

Request Callback

Get Latest Price

Product Brochure
Patient TypeAdult, Paediatric & Neonatal/Infant Ventilator(Optional)
Ventilation ModeInvasive & NIV
ApplicationICU & OT
BrandSchiller
Model Name/NumberGraphnet TS
Patient Age GroupPaediatric, Adult
Display12.1" TFT- LED colour touchscreen display
OptionalNeonatal ventilation, Adaptive Ventilatory Assistance, SBT, HFOT/HFNC, Endotracheal tube resistance

Minimum order quantity: 1 Piece

Mechanical ventilator that provides invasive and non-invasive ventilation for adult and paediatric patients, and for neonatal patients (Optional).
Features
  • Neonatal ventilation is available as option (installed or retrofit)
  • 12.1″ TFT- LED colour touchscreen display to view waveforms & loops simultaneously 
  • Tidal Volume correction according to BTPS leak compensation in all modes
  • Altitude and circuit compliance compensation with Leakage Compensation possible in all modes
  • Advanced modes like APRV, MMV+ Pressure Support, PSV+ assured Volume
  • PRVC – Pressure Regulated Volume Control, SIMV (PRVC) + PSV, VSV
  • Selectable apnea back up ventilation (Volume or Pressure type) 
  • 72 hours trend display
  • User adjustable ideal body weight factor
  • Integrated nebulizer (Volume compensated & Inspiratory Synchronize)
  • Advanced Lung Mechanism calculations: Auto-PEEP and trapped Volume, WOBi, Exp. Time Constant, P/ V Flex Monitoring, Slow Vital Capacity, Pi Max (NIF)
  • Suction % O2 for suction sequence with variable FiO2 Non-Invasive Ventilation available
Optional
  • Neonatal Ventilation with special modes available
  • AVA – Adaptive Ventilatory Assistance 
  • SBT – Spontaneous Breathing Trial and Stress Index
  • Oxygen Index PaFi
  • High Flow Oxygen Therapy (HFOT / HFNC)
  • Endotracheal tube resistance compensation: compensation of 10% – 100% for ET tube diameter Ø 2.5 – 12 mm (Optional & Upgradable) 

Schiller AQUILON TS Ventilator

Request Callback

Get Latest Price

Product Brochure
Patient TypeAdult, Paediatric & Infant Ventilator
Ventilation ModeInvasive & NIV
ApplicationICU & OT
Display Size12.1 inch
Requirement TypeNew
Model Name/NumberSchiller AQUILON TS
Ventilation ModesBoth IV and NIV ventilation available. APRV, MMV + Pressure Support, PSV + Assured Volume, and PRVC
Display12.1” TFT- LED colour touchscreen

Minimum order quantity: 1 Piece

AQUILON ts

Adult, Paediatric & Infant Ventilator

Features
  • Designed with high-end pneumatic base
  • A clear and complete display of vital sign variables on a built-in 12.1” TFT- LED colour touchscreen
  • Rapid-access keys and high visibility alarm indicator
  • User-friendly and intuitive programming
  • Auto-clavable & reusable rugged flow sensor
  • Invasive & Non Invasive ventilation available
  • Advanced modes like APRV, MMV + Pressure Support, PSV + Assured Volume, PRVC
  • Altitude and circuit compliance compensation with leakage compensation
  • 72 hours trend display
  • Integrated nebulizer (Volume compensated & Inspiratory Synchronize)
  • Advance lung mechanism calculations: Auto-PEEP and trapped volume, WOBi, exp. time constant, P/ V flex monitoring, slow vital capacity, Pi Max (NIF) 
  • Suction % O2 for suction sequence with variable FiO2

Neonatal Ventilator - Graphnet NEO

Request Callback

Get Latest Price

Product Brochure
Patient TypeNeonatal and Infant
Ventilation ModeTCPL, SIMV (TCPL) + PSV, N-CPAP, NIV, SIMV (PRVC) + PSV, VSV
ApplicationNICU & OT
BrandSchiller
Model Name/NumberGraphnet Neo
Patient Age GroupNeonatal
HumidifierExternal
Display12.1″ TFT – LED colour touchscreen display
ModesTCPL, SIMV (TCPL) + PSV, N-CPAP, NIV, SIMV (PRVC) + PSV, VSV

Minimum order quantity: 1 Piece

Dedicated Neonatal & Infant Ventilator.


Features
  • 12.1″ TFT – LED colour touchscreen display to view waveforms & loops  simultaneously
  • Proximal Flow Sensor at Y-piece for precise flow / volume monitoring and quick trigger response
  • Independent of circuit and humidifier compliance
  • Down to 2 ml at VC ventilation
  • Dedicated neonatal ventilation modes like TCPL, SIMV (TCPL) + PSV, N-CPAP, Non-Invasive Ventilation
  • SIMV (PRVC) + PSV, VSV (Volume Support Ventilation)
  • Pressure control and volume guaranteed with PRVC
  • High Flow Oxygen Therapy (HFOT/HFNC)
  • Automatic leakage compensation
  • Continuously automatically optimized trigger sensitivity (from 0.2 ml) & termination criteria
  • Selectable apnea back up ventilation (Volume or Pressure type)
  • Altitude and circuit compliance compensation & leak compensation in all modes 
  • Endotracheal tube resistance compensation: compensation of 10% – 100% for ET tube diameter Ø 2.5 – 6 mm 
  • Advance Lung Mechanism calculations: Auto-PEEP and Trapped Volume, Exp. Time Constant, Compliance and Resistance, Oxygen Index PaFi, C20/C, RVR Monitoring 
X

Contact Us

Gurkirpal Singh (Proprietor)
Abdura Systems
23218/3, Sector-68, Circular Road, Kumbra Village
Mohali - 140308, Punjab, India

Get Directions
Send Email
Share: